Skip to content

Commit

Permalink
Configuration example updated.
Browse files Browse the repository at this point in the history
  • Loading branch information
peter committed Feb 13, 2025
1 parent 4b95507 commit 240acf1
Showing 1 changed file with 3 additions and 1 deletion.
4 changes: 3 additions & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -341,6 +341,8 @@ fan_level_delay=2
# https://github.com/petersulyok/smfc?tab=readme-ov-file#3-swapped-zones
# (bool, default=0).
swapped_zones=0
# IPMI parameters for remote access (HOST is the BMC network address).
#remote_parameters=-U USERNAME -P PASSWORD -H HOST

[CPU zone]
# Fan controller enabled (bool, default=0)
Expand Down Expand Up @@ -439,7 +441,7 @@ Important notes:
My experience is that Noctua fans in my box are running stable in the 35-100% fan level interval. An additional user experience is (see [issue #12](https://github.com/petersulyok/smfc/issues/12)) when Noctua fans are paired with Ultra Low Noise Adapter the minimum stable fan level could go up to 45% (i.e. 35% is not stable).
3. `[CPU zone] / [HD zone] hwmon_path=`: This parameter is optional for Intel(R) CPUs and SATA drives (i.e. `smfc` can identify automatically the proper file locations), but must be specified manually for AMD(R) CPUs. In case of SAS/SCSI hard disks (where `drivetemp` cannot be loaded) you can specify `hddtemp` value. You can use wild characters (`?,*`) in this parameter and `smfc` will do the path resolution automatically.
4. `[Ipmi] remote_parameters=`: if you run your NAS in a Virtual Machine (e.g. you run TrueNAS Scale in a Proxmox VM with direct access on controller or HDDs) you would like to access IPMI remotely on your host. With this parameter your can specify IPMI remote parameters added to each IPMI calls (see [issue #27](https://github.com/petersulyok/smfc/issues/27)). Please note that the host address here is the BMC network address.
4. `[Ipmi] remote_parameters=`: if you run `smfc` in a Virtual Machine (e.g. you run TrueNAS Scale in a Proxmox VM with direct access on controller or HDDs) you would like to access IPMI remotely on your host. With this parameter your can specify IPMI remote parameters added to each IPMI calls (see [issue #27](https://github.com/petersulyok/smfc/issues/27)). Please note that the host address here is the BMC network address (not the VM host address).
5. Several sample configuration files are provided for different scenarios in folder `./src/samples`. Please take a look on them, it could be a good starting point in the creation of your own configuration.
### 12. Automatic execution of the service
Expand Down