Changed to base device datamoints, modified R15
Browse files Browse the repository at this point in the history
  • Loading branch information
eriknn committed Oct 13, 2024
1 parent 9ae8fbf commit 11d67bd
Show file tree
Hide file tree
Showing 6 changed files with 169 additions and 254 deletions.
3 changes: 1 addition & 2 deletions custom_components/swegon/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -51,8 +51,7 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
)

# Set up coordinator
coordinator = SwegonCoordinator(hass, dev, ip, port, slave_id,scan_interval, scan_interval_fast)
await coordinator._swegonDevice.async_load_device_data(device_model)
coordinator = SwegonCoordinator(hass, dev, device_model, ip, port, slave_id,scan_interval, scan_interval_fast)
hass.data[DOMAIN][entry.entry_id] = coordinator

# Forward the setup to the platforms.
Expand Down
4 changes: 2 additions & 2 deletions custom_components/swegon/coordinator.py
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,7 @@ class SwegonCoordinator(DataUpdateCoordinator):
_normal_poll_interval = 60
_fast_poll_interval = 10

def __init__(self, hass, device, ip, port, slave_id, scan_interval, scan_interval_fast):
def __init__(self, hass, device, device_module:str, ip, port, slave_id, scan_interval, scan_interval_fast):
"""Initialize coordinator parent"""
super().__init__(
hass,
Expand All @@ -31,7 +31,7 @@ def __init__(self, hass, device, ip, port, slave_id, scan_interval, scan_interva
self._fast_poll_interval = scan_interval_fast

self._device = device
self._swegonDevice = Swegon(ip, port, slave_id)
self._swegonDevice = Swegon(device_module, ip, port, slave_id)

# Initialize states
self._measurements = None
Expand Down
133 changes: 133 additions & 0 deletions custom_components/swegon/pyswegon/devices/casa_base.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,133 @@
import logging

from ..swegon import Modbus_Datapoint
from ..swegon import COMMANDS,SETPOINTS,DEVICE_INFO,ALARMS,SENSORS,SENSORS2,VIRTUALSENSORS,UNIT_STATUSES,CONFIG

_LOGGER = logging.getLogger(__name__)

class CasaBase:
def __init__(self):
self.Datapoints = {}

# Read / Write - Holding registers
self.Datapoints[COMMANDS] = {}
self.Datapoints[COMMANDS]["Op_Mode"] = Modbus_Datapoint(5000)
self.Datapoints[COMMANDS]["Fireplace_Mode"] = Modbus_Datapoint(5001)
self.Datapoints[COMMANDS]["Unused"] = Modbus_Datapoint(5002)
self.Datapoints[COMMANDS]["Travelling_Mode"] = Modbus_Datapoint(5003)

# Read / Write - Holding registers
self.Datapoints[SETPOINTS] = {}
self.Datapoints[SETPOINTS]["Temp_SP"] = Modbus_Datapoint(5100, 0.1)

# Read only - Input registers
self.Datapoints[DEVICE_INFO] = {}
self.Datapoints[DEVICE_INFO]["FW_Maj"] = Modbus_Datapoint(6000)
self.Datapoints[DEVICE_INFO]["FW_Min"] = Modbus_Datapoint(6001)
self.Datapoints[DEVICE_INFO]["FW_Build"] = Modbus_Datapoint(6002)
self.Datapoints[DEVICE_INFO]["Par_Maj"] = Modbus_Datapoint(6003)
self.Datapoints[DEVICE_INFO]["Par_Min"] = Modbus_Datapoint(6004)
self.Datapoints[DEVICE_INFO]["Model_Name"] = Modbus_Datapoint(6007) # 15 Bytes
self.Datapoints[DEVICE_INFO]["Serial_Number"] = Modbus_Datapoint(6023) # 24 Bytes

# Read only - Input registers
self.Datapoints[ALARMS] = {}
self.Datapoints[ALARMS]["T1_Failure"] = Modbus_Datapoint(6100)
self.Datapoints[ALARMS]["T2_Failure"] = Modbus_Datapoint(6101)
self.Datapoints[ALARMS]["T3_Failure"] = Modbus_Datapoint(6102)
self.Datapoints[ALARMS]["T4_Failure"] = Modbus_Datapoint(6103)
self.Datapoints[ALARMS]["T5_Failure"] = Modbus_Datapoint(6104)
self.Datapoints[ALARMS]["T6_Failure"] = Modbus_Datapoint(6105)
self.Datapoints[ALARMS]["T7_Failure"] = Modbus_Datapoint(6106)
self.Datapoints[ALARMS]["T8_Failure"] = Modbus_Datapoint(6107)
self.Datapoints[ALARMS]["T1_Failure_Unconf"] = Modbus_Datapoint(6108)
self.Datapoints[ALARMS]["T2_Failure_Unconf"] = Modbus_Datapoint(6109)
self.Datapoints[ALARMS]["T3_Failure_Unconf"] = Modbus_Datapoint(6110)
self.Datapoints[ALARMS]["T4_Failure_Unconf"] = Modbus_Datapoint(6111)
self.Datapoints[ALARMS]["T5_Failure_Unconf"] = Modbus_Datapoint(6112)
self.Datapoints[ALARMS]["T6_Failure_Unconf"] = Modbus_Datapoint(6113)
self.Datapoints[ALARMS]["T7_Failure_Unconf"] = Modbus_Datapoint(6114)
self.Datapoints[ALARMS]["T8_Failure_Unconf"] = Modbus_Datapoint(6115)
self.Datapoints[ALARMS]["Afterheater_Failure"] = Modbus_Datapoint(6116)
self.Datapoints[ALARMS]["Afterheater_Failure_Unconf"] = Modbus_Datapoint(6117)
self.Datapoints[ALARMS]["Preheater_Failure"] = Modbus_Datapoint(6118)
self.Datapoints[ALARMS]["Preheater_Failure_Unconf"] = Modbus_Datapoint(6119)
self.Datapoints[ALARMS]["Freezing_Danger"] = Modbus_Datapoint(6120)
self.Datapoints[ALARMS]["Freezing_Danger_Unconf"] = Modbus_Datapoint(6121)
self.Datapoints[ALARMS]["Internal_Error"] = Modbus_Datapoint(6122)
self.Datapoints[ALARMS]["Internal_Error_Unconf"] = Modbus_Datapoint(6123)
self.Datapoints[ALARMS]["Supply_Fan_Failure"] = Modbus_Datapoint(6124)
self.Datapoints[ALARMS]["Supply_Fan_Failure_Unconf"] = Modbus_Datapoint(6125)
self.Datapoints[ALARMS]["Exhaust_Fan_Failure"] = Modbus_Datapoint(6126)
self.Datapoints[ALARMS]["Exhaust_Fan_Failure_Unconf"] = Modbus_Datapoint(6127)
self.Datapoints[ALARMS]["Service_Info"] = Modbus_Datapoint(6128)
self.Datapoints[ALARMS]["Filter_Guard_Info"] = Modbus_Datapoint(6129)
self.Datapoints[ALARMS]["Emergency_Stop"] = Modbus_Datapoint(6130)
self.Datapoints[ALARMS]["Active_Alarms"] = Modbus_Datapoint(6131)
self.Datapoints[ALARMS]["Info_Unconf"] = Modbus_Datapoint(6132)

# Read only - Input registers
self.Datapoints[SENSORS] = {}
self.Datapoints[SENSORS]["Fresh_Temp"] = Modbus_Datapoint(6200, 0.1)
self.Datapoints[SENSORS]["Supply_Temp1"] = Modbus_Datapoint(6201, 0.1)
self.Datapoints[SENSORS]["Supply_Temp2"] = Modbus_Datapoint(6202, 0.1)
self.Datapoints[SENSORS]["Extract_Temp"] = Modbus_Datapoint(6203, 0.1)
self.Datapoints[SENSORS]["Exhaust_Temp"] = Modbus_Datapoint(6204, 0.1)
self.Datapoints[SENSORS]["Room_Temp"] = Modbus_Datapoint(6205, 0.1)
self.Datapoints[SENSORS]["UP1_Temp"] = Modbus_Datapoint(6206, 0.1)
self.Datapoints[SENSORS]["UP2_Temp"] = Modbus_Datapoint(6207, 0.1)
self.Datapoints[SENSORS]["WR_Temp"] = Modbus_Datapoint(6208, 0.1)
self.Datapoints[SENSORS]["PreHeat_Temp"] = Modbus_Datapoint(6209, 0.1)
self.Datapoints[SENSORS]["ExtFresh_Temp"] = Modbus_Datapoint(6210, 0.1)
self.Datapoints[SENSORS]["C02_Unf"] = Modbus_Datapoint(6211, 1.0)
self.Datapoints[SENSORS]["CO2_Fil"] = Modbus_Datapoint(6212, 1.0)
self.Datapoints[SENSORS]["RH"] = Modbus_Datapoint(6213, 1.0)
self.Datapoints[SENSORS]["AH"] = Modbus_Datapoint(6214, 0.1)
self.Datapoints[SENSORS]["AH_SP"] = Modbus_Datapoint(6215, 0.1)
self.Datapoints[SENSORS]["VOC"] = Modbus_Datapoint(6216, 1.0)
self.Datapoints[SENSORS]["Supply_Pressure"] = Modbus_Datapoint(6217, 1.0)
self.Datapoints[SENSORS]["Exhaust_Pressure"] = Modbus_Datapoint(6218, 1.0)
self.Datapoints[SENSORS]["Supply_Flow"] = Modbus_Datapoint(6219, 3.6)
self.Datapoints[SENSORS]["Exhaust_Flow"] = Modbus_Datapoint(6220, 3.6)

# Read only - Input registers
self.Datapoints[SENSORS2] = {}
self.Datapoints[SENSORS2]["Heat_Exchanger"] = Modbus_Datapoint(6233, 1.0)

# Virtual sensors (calculated)
self.Datapoints[VIRTUALSENSORS] = {}
self.Datapoints[VIRTUALSENSORS]["Efficiency"] = Modbus_Datapoint(0, 1)

# Read only - Input registers
self.Datapoints[UNIT_STATUSES] = {}
self.Datapoints[UNIT_STATUSES]["Unit_state"] = Modbus_Datapoint(6300)
self.Datapoints[UNIT_STATUSES]["Speed_state"] = Modbus_Datapoint(6301)
self.Datapoints[UNIT_STATUSES]["Supply_Fan"] = Modbus_Datapoint(6302)
self.Datapoints[UNIT_STATUSES]["Exhaust_Fan"] = Modbus_Datapoint(6303)
self.Datapoints[UNIT_STATUSES]["Supply_Fan_RPM"] = Modbus_Datapoint(6304)
self.Datapoints[UNIT_STATUSES]["Exhaust_Fan_RPM"] = Modbus_Datapoint(6305)
self.Datapoints[UNIT_STATUSES]["NotUsed1"] = Modbus_Datapoint(6306)
self.Datapoints[UNIT_STATUSES]["NotUsed2"] = Modbus_Datapoint(6307)
self.Datapoints[UNIT_STATUSES]["NotUsed3"] = Modbus_Datapoint(6308)
self.Datapoints[UNIT_STATUSES]["NotUsed4"] = Modbus_Datapoint(6309)
self.Datapoints[UNIT_STATUSES]["NotUsed5"] = Modbus_Datapoint(6310)
self.Datapoints[UNIT_STATUSES]["NotUsed6"] = Modbus_Datapoint(6311)
self.Datapoints[UNIT_STATUSES]["NotUsed7"] = Modbus_Datapoint(6312)
self.Datapoints[UNIT_STATUSES]["NotUsed8"] = Modbus_Datapoint(6313)
self.Datapoints[UNIT_STATUSES]["NotUsed9"] = Modbus_Datapoint(6314)
self.Datapoints[UNIT_STATUSES]["Temp_SP2"] = Modbus_Datapoint(6315)
self.Datapoints[UNIT_STATUSES]["Heating_Output"] = Modbus_Datapoint(6316)

# Read / Write - Holding registers
self.Datapoints[CONFIG] = {}
self.Datapoints[CONFIG]["Reset_Alarms"] = Modbus_Datapoint(5406) #5406
self.Datapoints[CONFIG]["Travelling_Mode_Speed_Drop"] = Modbus_Datapoint(5105) #5105
self.Datapoints[CONFIG]["Fireplace_Run_Time"] = Modbus_Datapoint(5103) #5103
self.Datapoints[CONFIG]["Fireplace_Max_Speed_Difference"] = Modbus_Datapoint(5104) #5104
self.Datapoints[CONFIG]["Night_Cooling"] = Modbus_Datapoint(5163) #5163
self.Datapoints[CONFIG]["Night_Cooling_FreshAir_Max"] = Modbus_Datapoint(5164) #5164
self.Datapoints[CONFIG]["Night_Cooling_FreshAir_Start"] = Modbus_Datapoint(5165) #5165
self.Datapoints[CONFIG]["Night_Cooling_RoomTemp_Start"] = Modbus_Datapoint(5166) #5166
self.Datapoints[CONFIG]["Night_Cooling_SupplyTemp_Min"] = Modbus_Datapoint(5167) #5167

_LOGGER.debug("Loaded base datapoints for Swegon Casa")
129 changes: 9 additions & 120 deletions custom_components/swegon/pyswegon/devices/casa_r15.py
Original file line number Diff line number Diff line change
@@ -1,125 +1,14 @@
import logging

from .casa_base import CasaBase
from ..swegon import Modbus_Datapoint
from ..swegon import COMMANDS,SETPOINTS,DEVICE_INFO,ALARMS,SENSORS,SENSORS2,VIRTUALSENSORS,UNIT_STATUSES,CONFIG

Datapoints = {}

# Read / Write - Holding registers
Datapoints[COMMANDS] = {}
Datapoints[COMMANDS]["Op_Mode"] = Modbus_Datapoint(5000)
Datapoints[COMMANDS]["Fireplace_Mode"] = Modbus_Datapoint(5001)
Datapoints[COMMANDS]["Unused"] = Modbus_Datapoint(5002)
Datapoints[COMMANDS]["Travelling_Mode"] = Modbus_Datapoint(5003)

# Read / Write - Holding registers
Datapoints[SETPOINTS] = {}
Datapoints[SETPOINTS]["Temp_SP"] = Modbus_Datapoint(5100, 0.01)

# Read only - Input registers
Datapoints[DEVICE_INFO] = {}
Datapoints[DEVICE_INFO]["FW_Maj"] = Modbus_Datapoint(6000)
Datapoints[DEVICE_INFO]["FW_Min"] = Modbus_Datapoint(6001)
Datapoints[DEVICE_INFO]["FW_Build"] = Modbus_Datapoint(6002)
Datapoints[DEVICE_INFO]["Par_Maj"] = Modbus_Datapoint(6003)
Datapoints[DEVICE_INFO]["Par_Min"] = Modbus_Datapoint(6004)
Datapoints[DEVICE_INFO]["Model_Name"] = Modbus_Datapoint(6007) # 15 Bytes
Datapoints[DEVICE_INFO]["Serial_Number"] = Modbus_Datapoint(6023) # 24 Bytes

# Read only - Input registers
Datapoints[ALARMS] = {}
Datapoints[ALARMS]["T1_Failure"] = Modbus_Datapoint(6100)
Datapoints[ALARMS]["T2_Failure"] = Modbus_Datapoint(6101)
Datapoints[ALARMS]["T3_Failure"] = Modbus_Datapoint(6102)
Datapoints[ALARMS]["T4_Failure"] = Modbus_Datapoint(6103)
Datapoints[ALARMS]["T5_Failure"] = Modbus_Datapoint(6104)
Datapoints[ALARMS]["T6_Failure"] = Modbus_Datapoint(6105)
Datapoints[ALARMS]["T7_Failure"] = Modbus_Datapoint(6106)
Datapoints[ALARMS]["T8_Failure"] = Modbus_Datapoint(6107)
Datapoints[ALARMS]["T1_Failure_Unconf"] = Modbus_Datapoint(6108)
Datapoints[ALARMS]["T2_Failure_Unconf"] = Modbus_Datapoint(6109)
Datapoints[ALARMS]["T3_Failure_Unconf"] = Modbus_Datapoint(6110)
Datapoints[ALARMS]["T4_Failure_Unconf"] = Modbus_Datapoint(6111)
Datapoints[ALARMS]["T5_Failure_Unconf"] = Modbus_Datapoint(6112)
Datapoints[ALARMS]["T6_Failure_Unconf"] = Modbus_Datapoint(6113)
Datapoints[ALARMS]["T7_Failure_Unconf"] = Modbus_Datapoint(6114)
Datapoints[ALARMS]["T8_Failure_Unconf"] = Modbus_Datapoint(6115)
Datapoints[ALARMS]["Afterheater_Failure"] = Modbus_Datapoint(6116)
Datapoints[ALARMS]["Afterheater_Failure_Unconf"] = Modbus_Datapoint(6117)
Datapoints[ALARMS]["Preheater_Failure"] = Modbus_Datapoint(6118)
Datapoints[ALARMS]["Preheater_Failure_Unconf"] = Modbus_Datapoint(6119)
Datapoints[ALARMS]["Freezing_Danger"] = Modbus_Datapoint(6120)
Datapoints[ALARMS]["Freezing_Danger_Unconf"] = Modbus_Datapoint(6121)
Datapoints[ALARMS]["Internal_Error"] = Modbus_Datapoint(6122)
Datapoints[ALARMS]["Internal_Error_Unconf"] = Modbus_Datapoint(6123)
Datapoints[ALARMS]["Supply_Fan_Failure"] = Modbus_Datapoint(6124)
Datapoints[ALARMS]["Supply_Fan_Failure_Unconf"] = Modbus_Datapoint(6125)
Datapoints[ALARMS]["Exhaust_Fan_Failure"] = Modbus_Datapoint(6126)
Datapoints[ALARMS]["Exhaust_Fan_Failure_Unconf"] = Modbus_Datapoint(6127)
Datapoints[ALARMS]["Service_Info"] = Modbus_Datapoint(6128)
Datapoints[ALARMS]["Filter_Guard_Info"] = Modbus_Datapoint(6129)
Datapoints[ALARMS]["Emergency_Stop"] = Modbus_Datapoint(6130)
Datapoints[ALARMS]["Active_Alarms"] = Modbus_Datapoint(6131)
Datapoints[ALARMS]["Info_Unconf"] = Modbus_Datapoint(6132)

# Read only - Input registers
Datapoints[SENSORS] = {}
Datapoints[SENSORS]["Fresh_Temp"] = Modbus_Datapoint(6200, 0.1)
Datapoints[SENSORS]["Supply_Temp1"] = Modbus_Datapoint(6201, 0.1)
Datapoints[SENSORS]["Supply_Temp2"] = Modbus_Datapoint(6202, 0.1)
Datapoints[SENSORS]["Extract_Temp"] = Modbus_Datapoint(6203, 0.1)
Datapoints[SENSORS]["Exhaust_Temp"] = Modbus_Datapoint(6204, 0.1)
Datapoints[SENSORS]["Room_Temp"] = Modbus_Datapoint(6205, 0.1)
Datapoints[SENSORS]["UP1_Temp"] = Modbus_Datapoint(6206, 0.1)
Datapoints[SENSORS]["UP2_Temp"] = Modbus_Datapoint(6207, 0.1)
Datapoints[SENSORS]["WR_Temp"] = Modbus_Datapoint(6208, 0.1)
Datapoints[SENSORS]["PreHeat_Temp"] = Modbus_Datapoint(6209, 0.1)
Datapoints[SENSORS]["ExtFresh_Temp"] = Modbus_Datapoint(6210, 0.1)
Datapoints[SENSORS]["C02_Unf"] = Modbus_Datapoint(6211, 1.0)
Datapoints[SENSORS]["CO2_Fil"] = Modbus_Datapoint(6212, 1.0)
Datapoints[SENSORS]["RH"] = Modbus_Datapoint(6213, 1.0)
Datapoints[SENSORS]["AH"] = Modbus_Datapoint(6214, 0.1)
Datapoints[SENSORS]["AH_SP"] = Modbus_Datapoint(6215, 0.1)
Datapoints[SENSORS]["VOC"] = Modbus_Datapoint(6216, 1.0)
Datapoints[SENSORS]["Supply_Pressure"] = Modbus_Datapoint(6217, 1.0)
Datapoints[SENSORS]["Exhaust_Pressure"] = Modbus_Datapoint(6218, 1.0)
Datapoints[SENSORS]["Supply_Flow"] = Modbus_Datapoint(6219, 3.6)
Datapoints[SENSORS]["Exhaust_Flow"] = Modbus_Datapoint(6220, 3.6)

# Read only - Input registers
Datapoints[SENSORS2] = {}
Datapoints[SENSORS2]["Heat_Exchanger"] = Modbus_Datapoint(6233, 1.0)

# Virtual sensors (calculated)
Datapoints[VIRTUALSENSORS] = {}
Datapoints[VIRTUALSENSORS]["Efficiency"] = Modbus_Datapoint(0, 1)
_LOGGER = logging.getLogger(__name__)

# Read only - Input registers
Datapoints[UNIT_STATUSES] = {}
Datapoints[UNIT_STATUSES]["Unit_state"] = Modbus_Datapoint(6300)
Datapoints[UNIT_STATUSES]["Speed_state"] = Modbus_Datapoint(6301)
Datapoints[UNIT_STATUSES]["Supply_Fan"] = Modbus_Datapoint(6302)
Datapoints[UNIT_STATUSES]["Exhaust_Fan"] = Modbus_Datapoint(6303)
Datapoints[UNIT_STATUSES]["Supply_Fan_RPM"] = Modbus_Datapoint(6304)
Datapoints[UNIT_STATUSES]["Exhaust_Fan_RPM"] = Modbus_Datapoint(6305)
Datapoints[UNIT_STATUSES]["NotUsed1"] = Modbus_Datapoint(6306)
Datapoints[UNIT_STATUSES]["NotUsed2"] = Modbus_Datapoint(6307)
Datapoints[UNIT_STATUSES]["NotUsed3"] = Modbus_Datapoint(6308)
Datapoints[UNIT_STATUSES]["NotUsed4"] = Modbus_Datapoint(6309)
Datapoints[UNIT_STATUSES]["NotUsed5"] = Modbus_Datapoint(6310)
Datapoints[UNIT_STATUSES]["NotUsed6"] = Modbus_Datapoint(6311)
Datapoints[UNIT_STATUSES]["NotUsed7"] = Modbus_Datapoint(6312)
Datapoints[UNIT_STATUSES]["NotUsed8"] = Modbus_Datapoint(6313)
Datapoints[UNIT_STATUSES]["NotUsed9"] = Modbus_Datapoint(6314)
Datapoints[UNIT_STATUSES]["Temp_SP2"] = Modbus_Datapoint(6315)
Datapoints[UNIT_STATUSES]["Heating_Output"] = Modbus_Datapoint(6316)
class CasaR15(CasaBase):
def __init__(self):
super().__init__()
self.Datapoints[SETPOINTS]["Temp_SP"] = Modbus_Datapoint(5100, 0.01)

# Read / Write - Holding registers
Datapoints[CONFIG] = {}
Datapoints[CONFIG]["Reset_Alarms"] = Modbus_Datapoint(5406) #5406
Datapoints[CONFIG]["Travelling_Mode_Speed_Drop"] = Modbus_Datapoint(5105) #5105
Datapoints[CONFIG]["Fireplace_Run_Time"] = Modbus_Datapoint(5103) #5103
Datapoints[CONFIG]["Fireplace_Max_Speed_Difference"] = Modbus_Datapoint(5104) #5104
Datapoints[CONFIG]["Night_Cooling"] = Modbus_Datapoint(5163) #5163
Datapoints[CONFIG]["Night_Cooling_FreshAir_Max"] = Modbus_Datapoint(5164) #5164
Datapoints[CONFIG]["Night_Cooling_FreshAir_Start"] = Modbus_Datapoint(5165) #5165
Datapoints[CONFIG]["Night_Cooling_RoomTemp_Start"] = Modbus_Datapoint(5166) #5166
Datapoints[CONFIG]["Night_Cooling_SupplyTemp_Min"] = Modbus_Datapoint(5167) #5167
_LOGGER.debug("Loaded datapoints for Swegon Casa R15")