Notifications
You must be signed in to change notification settings - Fork 7
/
Copy pathLVHDoISCSISR7.patch
48 lines (44 loc) · 2.3 KB
/
LVHDoISCSISR7.patch
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
--- a/LVHDoISCSISR.py 2016-05-30 14:48:25.000000000 +1000
+++ b/LVHDoISCSISR.py 2016-05-30 14:48:36.000000000 +1000
@@ -18,7 +18,7 @@
# LVHDoISCSISR: LVHD over ISCSI software initiator SR driver
#
-import SR, VDI, LVHDSR, BaseISCSI, SRCommand, util, scsiutil, lvutil
+import SR, VDI, LVHDSR, RBDSR, BaseISCSI, SRCommand, util, scsiutil, lvutil
import statvfs, time
import os, socket, sys, re
import xs_errors
@@ -79,7 +79,11 @@
if self.original_srcmd.dconf.has_key('target'):
self.original_srcmd.dconf['targetlist'] = self.original_srcmd.dconf['target']
- iscsi = BaseISCSI.BaseISCSISR(self.original_srcmd, sr_uuid)
+
+ if self.original_srcmd.dconf.has_key('port') and '6789' in self.original_srcmd.dconf['port']:
+ iscsi = RBDSR.RBDSR(self.original_srcmd, sr_uuid)
+ else:
+ iscsi = BaseISCSI.BaseISCSISR(self.original_srcmd, sr_uuid)
self.iscsiSRs = []
self.iscsiSRs.append(iscsi)
@@ -144,7 +148,10 @@
srcmd_copy.dconf['targetIQN'] = iqn
srcmd_copy.dconf['multiSession'] = IQNstring
util.SMlog("Setting targetlist: %s" % srcmd_copy.dconf['targetlist'])
- self.iscsiSRs.append(BaseISCSI.BaseISCSISR(srcmd_copy, sr_uuid))
+ if self.original_srcmd.dconf.has_key('port') and '6789' in self.original_srcmd.dconf['port']:
+ self.iscsiSRs.append(RBDSR.RBDSR(srcmd_copy, sr_uuid))
+ else:
+ self.iscsiSRs.append(BaseISCSI.BaseISCSISR(srcmd_copy, sr_uuid))
pbd = util.find_my_pbd(self.session, self.host_ref, self.sr_ref)
if pbd <> None and not self.dconf.has_key('multiSession'):
dconf = self.session.xenapi.PBD.get_device_config(pbd)
@@ -557,7 +564,10 @@
raise xs_errors.XenError('InvalidDev')
self._pathrefresh(LVHDoISCSISR)
out = LVHDSR.LVHDSR.probe(self)
- self.iscsi.detach(self.uuid)
+ if self.original_srcmd.dconf.has_key('port') and '6789' in self.original_srcmd.dconf['port']:
+ util.SMlog('This is RBD SR, we don\'t attach target during probing so no detach required')
+ else:
+ self.iscsi.detach(self.uuid)
return out