You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
function B = magnetic_flux_three_coil(x, y, z, I_x, I_y, I_z, a, N, quat, split)
%半径a,巻き数Nの3つのコイルにI_x,I_y,I_zの電流が流れたときに(x, y, z)に発生する磁場
% Detailed explanation goes here
%split = 32;
B = magnetic_flux_x2(x, y, z, I_x, a, N, quat, split) + magnetic_flux_y2(x, y, z, I_y, a, N, quat, split) + magnetic_flux_z2(x, y, z, I_z, a, N, quat, split);
%B = magnetic_flux_x2(x, y, z, I_x, a, N, p, q, l) ;