Notifications
You must be signed in to change notification settings - Fork 58
/
Copy pathEVSE_1.json
134 lines (134 loc) · 3.48 KB
/
EVSE_1.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
{
"$schema": "http://json-schema.org/draft-07/schema#",
"description": "Schema for EVSE",
"type": "object",
"name": "EVSE",
"evse_id": 1,
"properties": {
"EVSEAllowReset": {
"variable_name": "AllowReset",
"characteristics": {
"supportsMonitoring": true,
"dataType": "boolean"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly"
}
],
"description": "Can be used to announce that an EVSE can be reset individually",
"type": "boolean"
},
"EVSEAvailabilityState": {
"variable_name": "AvailabilityState",
"characteristics": {
"supportsMonitoring": true,
"dataType": "OptionList",
"valuesList": "Available,Occupied,Reserved,Unavailable,Faulted"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly"
}
],
"description": "This variable reports current availability state for the EVSE",
"type": "string",
"default": "Unavailable"
},
"EVSEAvailable": {
"variable_name": "Available",
"characteristics": {
"supportsMonitoring": true,
"dataType": "boolean"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly",
"value": true
}
],
"description": "Component exists",
"type": "boolean",
"default": false
},
"EvseId": {
"variable_name": "EvseId",
"characteristics": {
"supportsMonitoring": true,
"dataType": "string"
},
"attributes": [
{
"type": "Actual"
}
],
"description": "The name of the EVSE in the string format as required by ISO 15118 and IEC 63119-2.",
"type": "string"
},
"EVSEPower": {
"variable_name": "Power",
"characteristics": {
"unit": "W",
"maxLimit": 22000,
"supportsMonitoring": true,
"dataType": "decimal"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly"
},
{
"type": "MaxSet",
"mutability": "ReadOnly"
}
],
"description": " kW,The variableCharacteristic maxLimit, that holds the maximum power that this EVSE can provide, is required. The Actual value of the instantaneous (real) power is desired, but not required.",
"type": "number",
"default": "0"
},
"EVSESupplyPhases": {
"variable_name": "SupplyPhases",
"characteristics": {
"supportsMonitoring": true,
"dataType": "integer"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly",
"value": 3
}
],
"description": "Number of alternating current phases connected/available.",
"type": "integer",
"default": "0"
},
"ISO15118EvseId": {
"variable_name": "ISO15118EvseId",
"characteristics": {
"supportsMonitoring": true,
"dataType": "string",
"minLimit": 7,
"maxLimit": 37
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadWrite"
}
],
"description": "The name of the EVSE in the string format as required by ISO 15118 and IEC 63119-2. Example: \"DE*ICE*E*1234567890*1\"",
"type": "string"
}
},
"required": [
"EVSEAvailabilityState",
"EVSEAvailable",
"EVSEPower",
"EVSESupplyPhases"
]
}