You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I have a nozzle camera that is now going offline a lot. It shows as no signal, and had been working for about 6 months. It seems to happen when I heat up the build plate. The canbus toolhead is showing a temp of 36 degrees, although its further away. The decoder board is outside of the enclosure and could be seeing more heat. Is there anything I can do to prevent this from happening? Should a longer ribbon cable be purchased to move the decoder further away, or is it inside the camera that is overheating? Can I install heatsinks on components?
Thanks
The text was updated successfully, but these errors were encountered:
I have a nozzle camera that is now going offline a lot. It shows as no signal, and had been working for about 6 months. It seems to happen when I heat up the build plate. The canbus toolhead is showing a temp of 36 degrees, although its further away. The decoder board is outside of the enclosure and could be seeing more heat. Is there anything I can do to prevent this from happening? Should a longer ribbon cable be purchased to move the decoder further away, or is it inside the camera that is overheating? Can I install heatsinks on components?
Thanks
The text was updated successfully, but these errors were encountered: